Cryogenic Valve - Safety Angular Relief / Thermal 90º
.: sem foto
References:
Temperature:
Service Pressure
SM-40
Maximum:
160º
Maximum:
60 BAR
2003 series
Minimum:
-196º
Minimum:
2 BAR
1
Upper Bonnet
Bronze
2
Ring
PTFE
3
Spring Guide
Brass
4
Spring
Stainless Steel
5
Lock-nut
Brass
6
Lacre
Brass
7
Body
Bronze
8
Lower Spring Guide
Brass
9
Obturator
PTFE / Kel-F
10
Lower Bonnet
Brass
click on image to enlarge
Repair Kit:
Item 9
DN
mm
inc
15
1/2"
20
3/4"
25
1"
A
50
50
50
B
70
70
70
C
120
120
120
D
190
190
190
Weight (Kg)
1.65
1.70
1.75
The valves are supplied clean and ready degreased for the use with Oxygen
At requesting, specify the opening pressure
Subject the modifications without previous warning.