Versão em Português Español English Version

Cryogenic Valve - Regulator Auto Compensed Piloted

.: click to enlarge
References:   Temperature:   Test   Service Pressure
RP-44-DB   Maximum: n/d   Hydrostatic: 60 BAR   Initial Pressure: 40 BAR
gas phase   Minimum: n/d         Regulate: 1 to 30 BAR
                   
1 Bonnet Bronze
2 Pulse disk Bronze
3 Diaphragm Viton
4 Support Disk Brass
5 Conical Spring Stainless Steel
6 Elastic Ring Steel
7 Guide Disk Brass
8 Command Stem Stainless Steel
9 O´Ring Viton
10 Seal Support Brass
11 Screw Stainless Steel
12 Seal Viton
13 Obturator Brass
14 Body Bronze
15 Ring Joins Brass
16 Gasket PTFE
17 Cover Bronze
18 Cylinder Brass
19 Spring Stainless Steel
20 O´Ring Viton
21 Screw Nut Brass
22 Screw Brass
Clique para ampliar

click on image to enlarge

Repair Kit: Items (3-9-10-12-16-20)     Note: Valve for installations in:: Hidrogen, Nitrogen, Argon and Oxygen  
               
DN mm
inc
15
1/2"
20
3/4"
25
1"
50
2"
   
A 110 110 110 200            
B 50 50 50 95            
C 90 90 90 125            
Weight (Kg) 4.90 5.10 5.50 13.00            

The valves are supplied clean and ready degreased for the use with Oxygen
At requesting, specify the Service Pressure
Subject the modifications without previous warning.
Conheça a WebComm Interactive Media!